CKS=MCK, START=CONTINUOUS, CKG=NONE, CKO=NONE
Transmit Clock Mode Register
CKS | Transmit Clock Selection 0 (MCK): Divided Clock 1 (TK): TK Clock signal 2 (RK): RK pin |
CKO | Transmit Clock Output Mode Selection 0 (NONE): None 1 (CONTINUOUS): Continuous Receive Clock 2 (TRANSFER): Transmit Clock only during data transfers |
CKI | Transmit Clock Inversion |
CKG | Transmit Clock Gating Selection 0 (NONE): None 1 (CONTINUOUS): Transmit Clock enabled only if TF Low 2 (TRANSFER): Transmit Clock enabled only if TF High |
START | Transmit Start Selection 0 (CONTINUOUS): Continuous, as soon as a word is written in the SSC_THR Register (if Transmit is enabled), and immediately after the end of transfer of the previous data. 1 (RECEIVE): Receive start 2 (RF_LOW): Detection of a low level on TF signal 3 (RF_HIGH): Detection of a high level on TF signal 4 (RF_FALLING): Detection of a falling edge on TF signal 5 (RF_RISING): Detection of a rising edge on TF signal 6 (RF_LEVEL): Detection of any level change on TF signal 7 (RF_EDGE): Detection of any edge on TF signal 8 (CMP_0): Compare 0 |
STTDLY | Transmit Start Delay |
PERIOD | Transmit Period Divider Selection |