Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as SR

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (NO)WKUPS 0 (NO)SMWS 0 (NO)BODRSTS 0 (NO)SMRSTS 0 (NO)SMS 0 (HIGH)SMOS 0 (RC)OSCSEL 0 (DIS)WKUPIS0 0 (DIS)WKUPIS1 0 (DIS)WKUPIS2 0 (DIS)WKUPIS3 0 (DIS)WKUPIS4 0 (DIS)WKUPIS5 0 (DIS)WKUPIS6 0 (DIS)WKUPIS7 0 (DIS)WKUPIS8 0 (DIS)WKUPIS9 0 (DIS)WKUPIS10 0 (DIS)WKUPIS11 0 (DIS)WKUPIS12 0 (DIS)WKUPIS13 0 (DIS)WKUPIS14 0 (DIS)WKUPIS15

WKUPIS10=DIS, WKUPIS7=DIS, OSCSEL=RC, WKUPIS14=DIS, SMOS=HIGH, WKUPIS9=DIS, WKUPIS13=DIS, WKUPIS1=DIS, BODRSTS=NO, WKUPIS11=DIS, WKUPIS15=DIS, WKUPIS12=DIS, WKUPIS5=DIS, WKUPIS0=DIS, WKUPIS6=DIS, SMS=NO, SMRSTS=NO, SMWS=NO, WKUPIS3=DIS, WKUPIS4=DIS, WKUPS=NO, WKUPIS2=DIS, WKUPIS8=DIS

Description

Supply Controller Status Register

Fields

WKUPS

WKUP Wake Up Status

0 (NO): no wake up due to the assertion of the WKUP pins has occurred since the last read of SUPC_SR.

1 (PRESENT): at least one wake up due to the assertion of the WKUP pins has occurred since the last read of SUPC_SR.

SMWS

Supply Monitor Detection Wake Up Status

0 (NO): no wake up due to a supply monitor detection has occurred since the last read of SUPC_SR.

1 (PRESENT): at least one wake up due to a supply monitor detection has occurred since the last read of SUPC_SR.

BODRSTS

Brownout Detector Reset Status

0 (NO): no core brownout rising edge event has been detected since the last read of the SUPC_SR.

1 (PRESENT): at least one brownout output rising edge event has been detected since the last read of the SUPC_SR.

SMRSTS

Supply Monitor Reset Status

0 (NO): no supply monitor detection has generated a core reset since the last read of the SUPC_SR.

1 (PRESENT): at least one supply monitor detection has generated a core reset since the last read of the SUPC_SR.

SMS

Supply Monitor Status

0 (NO): no supply monitor detection since the last read of SUPC_SR.

1 (PRESENT): at least one supply monitor detection since the last read of SUPC_SR.

SMOS

Supply Monitor Output Status

0 (HIGH): the supply monitor detected VDDIO higher than its threshold at its last measurement.

1 (LOW): the supply monitor detected VDDIO lower than its threshold at its last measurement.

OSCSEL

32-kHz Oscillator Selection Status

0 (RC): the slow clock, SLCK is generated by the embedded 32-kHz RC oscillator.

1 (CRYST): the slow clock, SLCK is generated by the 32-kHz crystal oscillator.

WKUPIS0

WKUP Input Status 0

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS1

WKUP Input Status 1

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS2

WKUP Input Status 2

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS3

WKUP Input Status 3

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS4

WKUP Input Status 4

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS5

WKUP Input Status 5

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS6

WKUP Input Status 6

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS7

WKUP Input Status 7

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS8

WKUP Input Status 8

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS9

WKUP Input Status 9

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS10

WKUP Input Status 10

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS11

WKUP Input Status 11

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS12

WKUP Input Status 12

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS13

WKUP Input Status 13

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS14

WKUP Input Status 14

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

WKUPIS15

WKUP Input Status 15

0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event.

1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event.

Links

()