Atmel /ATSAM3N1B /ADC /MR

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as MR

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (DIS)TRGEN 0 (ADC_TRIG0)TRGSEL 0 (BITS_10)LOWRES 0 (NORMAL)SLEEP 0 (OFF)FWUP 0 (OFF)FREERUN 0PRESCAL0 (SUT0)STARTUP0TRACKTIM 0 (NUM_ORDER)USEQ

USEQ=NUM_ORDER, FWUP=OFF, STARTUP=SUT0, LOWRES=BITS_10, TRGEN=DIS, SLEEP=NORMAL, FREERUN=OFF, TRGSEL=ADC_TRIG0

Description

Mode Register

Fields

TRGEN

Trigger Enable

0 (DIS): Hardware triggers are disabled. Starting a conversion is only possible by software.

1 (EN): Hardware trigger selected by TRGSEL field is enabled.

TRGSEL

Trigger Selection

0 (ADC_TRIG0): External trigger

1 (ADC_TRIG1): TIO Output of the Timer Counter Channel 0

2 (ADC_TRIG2): TIO Output of the Timer Counter Channel 1

3 (ADC_TRIG3): TIO Output of the Timer Counter Channel 2

LOWRES

Resolution

0 (BITS_10): 10-bit resolution

1 (BITS_8): 8-bit resolution

SLEEP

Sleep Mode

0 (NORMAL): Normal Mode: The ADC Core and reference voltage circuitry are kept ON between conversions

1 (SLEEP): Sleep Mode: The ADC Core and reference voltage circuitry are OFF between conversions

FWUP

Fast Wake Up

0 (OFF): Normal Sleep Mode: The sleep mode is defined by the SLEEP bit

1 (ON): Fast Wake Up Sleep Mode: The Voltage reference is ON between conversions and ADC Core is OFF

FREERUN

Free Run Mode

0 (OFF): Normal Mode

1 (ON): Free Run Mode: Never wait for any trigger.

PRESCAL

Prescaler Rate Selection

STARTUP

Start Up Time

0 (SUT0): 0 periods of ADCClock

1 (SUT8): 8 periods of ADCClock

2 (SUT16): 16 periods of ADCClock

3 (SUT24): 24 periods of ADCClock

4 (SUT64): 64 periods of ADCClock

5 (SUT80): 80 periods of ADCClock

6 (SUT96): 96 periods of ADCClock

7 (SUT112): 112 periods of ADCClock

8 (SUT512): 512 periods of ADCClock

9 (SUT576): 576 periods of ADCClock

10 (SUT640): 640 periods of ADCClock

11 (SUT704): 704 periods of ADCClock

12 (SUT768): 768 periods of ADCClock

13 (SUT832): 832 periods of ADCClock

14 (SUT896): 896 periods of ADCClock

15 (SUT960): 960 periods of ADCClock

TRACKTIM

Tracking Time

USEQ

Use Sequence Enable

0 (NUM_ORDER): Normal Mode: The controller converts channels in a simple numeric order.

1 (REG_ORDER): User Sequence Mode: The sequence respects what is defined in ADC_SEQR1 and ADC_SEQR2 registers.