OSCBYPASS=NO_EFFECT, VDDIORDY=VDDIO_REMOVED, BODDIS=ENABLE, BODRSTEN=NOT_ENABLE
Supply Controller Mode Register
BODRSTEN | Brownout Detector Reset Enable 0 (NOT_ENABLE): the core reset signal “vddcore_nreset” is not affected when a brownout detection occurs. 1 (ENABLE): the core reset signal, vddcore_nreset is asserted when a brownout detection occurs. |
BODDIS | Brownout Detector Disable 0 (ENABLE): the core brownout detector is enabled. 1 (DISABLE): the core brownout detector is disabled. |
VDDIORDY | VDDIO Ready 0 (VDDIO_REMOVED): VDDIO is removed (used before going to backup mode when backup batteries are used) 1 (VDDIO_PRESENT): VDDIO is present (used before going to backup mode when backup batteries are used) |
OSCBYPASS | Oscillator Bypass 0 (NO_EFFECT): no effect. Clock selection depends on XTALSEL value. 1 (BYPASS): the 32-KHz XTAL oscillator is selected and is put in bypass mode. |
KEY | Password Key 165 (PASSWD): Writing any other value in this field aborts the write operation. |