WKUPIS10=DIS, WKUPIS6=DIS, WKUPIS2=DIS, WKUPIS1=DIS, WKUPIS7=DIS, SMRSTS=NO, WKUPIS5=DIS, BODRSTS=NO, WKUPIS15=DIS, WKUPIS4=DIS, WKUPIS9=DIS, WKUPIS13=DIS, WKUPIS3=DIS, FWUPIS=LOW, SMS=NO, OSCSEL=RC, WKUPIS14=DIS, SMWS=NO, SMOS=HIGH, WKUPS=NO, WKUPIS0=DIS, WKUPIS12=DIS, FWUPS=NO, WKUPIS8=DIS, WKUPIS11=DIS
Supply Controller Status Register
FWUPS | FWUP Wake-up Status 0 (NO): no wake-up due to the assertion of the FWUP pin has occurred since the last read of SUPC_SR. 1 (PRESENT): at least one wake-up due to the assertion of the FWUP pin has occurred since the last read of SUPC_SR. |
WKUPS | WKUP Wake-up Status 0 (NO): no wake-up due to the assertion of the WKUP pins has occurred since the last read of SUPC_SR. 1 (PRESENT): at least one wake-up due to the assertion of the WKUP pins has occurred since the last read of SUPC_SR. |
SMWS | Supply Monitor Detection Wake-up Status 0 (NO): no wake-up due to a supply monitor detection has occurred since the last read of SUPC_SR. 1 (PRESENT): at least one wake-up due to a supply monitor detection has occurred since the last read of SUPC_SR. |
BODRSTS | Brownout Detector Reset Status 0 (NO): no core brownout rising edge event has been detected since the last read of the SUPC_SR. 1 (PRESENT): at least one brownout output rising edge event has been detected since the last read of the SUPC_SR. |
SMRSTS | Supply Monitor Reset Status 0 (NO): no supply monitor detection has generated a core reset since the last read of the SUPC_SR. 1 (PRESENT): at least one supply monitor detection has generated a core reset since the last read of the SUPC_SR. |
SMS | Supply Monitor Status 0 (NO): no supply monitor detection since the last read of SUPC_SR. 1 (PRESENT): at least one supply monitor detection since the last read of SUPC_SR. |
SMOS | Supply Monitor Output Status 0 (HIGH): the supply monitor detected VDDUTMI higher than its threshold at its last measurement. 1 (LOW): the supply monitor detected VDDUTMI lower than its threshold at its last measurement. |
OSCSEL | 32-kHz Oscillator Selection Status 0 (RC): the slow clock, SLCK is generated by the embedded 32-kHz RC oscillator. 1 (CRYST): the slow clock, SLCK is generated by the 32-kHz crystal oscillator. |
FWUPIS | FWUP Input Status 0 (LOW): FWUP input is tied low. 1 (HIGH): FWUP input is tied high. |
WKUPIS0 | WKUP Input Status 0 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS1 | WKUP Input Status 1 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS2 | WKUP Input Status 2 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS3 | WKUP Input Status 3 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS4 | WKUP Input Status 4 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS5 | WKUP Input Status 5 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS6 | WKUP Input Status 6 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS7 | WKUP Input Status 7 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS8 | WKUP Input Status 8 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS9 | WKUP Input Status 9 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS10 | WKUP Input Status 10 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS11 | WKUP Input Status 11 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS12 | WKUP Input Status 12 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS13 | WKUP Input Status 13 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS14 | WKUP Input Status 14 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |
WKUPIS15 | WKUP Input Status 15 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake-up event. |