SELMINUS=TS, SELPLUS=AD0, FE=DIS, EDGETYP=RISING, SELFS=CE, INV=DIS, ACEN=DIS
Mode Register
SELMINUS | Selection for Minus Comparator Input 0 (TS): Select TS 1 (ADVREF): Select ADVREF 2 (DAC0): Select DAC0 3 (DAC1): Select DAC1 4 (AD0): Select AD0 5 (AD1): Select AD1 6 (AD2): Select AD2 7 (AD3): Select AD3 |
SELPLUS | Selection For Plus Comparator Input 0 (AD0): Select AD0 1 (AD1): Select AD1 2 (AD2): Select AD2 3 (AD3): Select AD3 4 (AD4): Select AD4 5 (AD5): Select AD5 6 (AD6): Select AD6 7 (AD7): Select AD7 |
ACEN | Analog Comparator Enable 0 (DIS): Analog comparator disabled. 1 (EN): Analog comparator enabled. |
EDGETYP | Edge Type 0 (RISING): Only rising edge of comparator output 1 (FALLING): Falling edge of comparator output 2 (ANY): Any edge of comparator output |
INV | Invert Comparator Output 0 (DIS): Analog comparator output is directly processed. 1 (EN): Analog comparator output is inverted prior to being processed. |
SELFS | Selection Of Fault Source 0 (CE): The CE flag is used to drive the FAULT output. 1 (OUTPUT): The output of the analog comparator flag is used to drive the FAULT output. |
FE | Fault Enable 0 (DIS): The FAULT output is tied to 0. 1 (EN): The FAULT output is driven by the signal defined by SELFS. |