WKUPIS10=DIS, LPDBCS1=NO, LPDBCS0=NO, WKUPIS2=DIS, SMWS=NO, WKUPIS13=DIS, WKUPIS1=DIS, OSCSEL=RC, SMRSTS=NO, SMS=NO, WKUPIS14=DIS, WKUPIS4=DIS, WKUPIS7=DIS, WKUPIS11=DIS, WKUPIS8=DIS, WKUPIS6=DIS, SMOS=HIGH, BODRSTS=NO, WKUPS=NO, WKUPIS15=DIS, WKUPIS12=DIS, WKUPIS3=DIS, WKUPIS9=DIS, WKUPIS5=DIS, WKUPIS0=DIS
Supply Controller Status Register
WKUPS | WKUP Wake-up Status (cleared on read) 0 (NO): No wake-up due to the assertion of the WKUP pins has occurred since the last read of SUPC_SR. 1 (PRESENT): At least one wake-up due to the assertion of the WKUP pins has occurred since the last read of SUPC_SR. |
SMWS | Supply Monitor Detection Wake-up Status (cleared on read) 0 (NO): No wake-up due to a supply monitor detection has occurred since the last read of SUPC_SR. 1 (PRESENT): At least one wake-up due to a supply monitor detection has occurred since the last read of SUPC_SR. |
BODRSTS | Brownout Detector Reset Status (cleared on read) 0 (NO): No core brownout rising edge event has been detected since the last read of the SUPC_SR. 1 (PRESENT): At least one brownout output rising edge event has been detected since the last read of the SUPC_SR. |
SMRSTS | Supply Monitor Reset Status (cleared on read) 0 (NO): No supply monitor detection has generated a core reset since the last read of the SUPC_SR. 1 (PRESENT): At least one supply monitor detection has generated a core reset since the last read of the SUPC_SR. |
SMS | Supply Monitor Status (cleared on read) 0 (NO): No supply monitor detection since the last read of SUPC_SR. 1 (PRESENT): At least one supply monitor detection since the last read of SUPC_SR. |
SMOS | Supply Monitor Output Status 0 (HIGH): The supply monitor detected VDDIO higher than its threshold at its last measurement. 1 (LOW): The supply monitor detected VDDIO lower than its threshold at its last measurement. |
OSCSEL | 32-kHz Oscillator Selection Status 0 (RC): The slow clock, SLCK, is generated by the embedded 32 kHz RC oscillator. 1 (CRYST): The slow clock, SLCK, is generated by the 32 kHz crystal oscillator. |
LPDBCS0 | Low-power Debouncer Wake-up Status on WKUP0 (cleared on read) 0 (NO): No wake-up due to the assertion of the WKUP0 pin has occurred since the last read of SUPC_SR. 1 (PRESENT): At least one wake-up due to the assertion of the WKUP0 pin has occurred since the last read of SUPC_SR. |
LPDBCS1 | Low-power Debouncer Wake-up Status on WKUP1 (cleared on read) 0 (NO): No wake-up due to the assertion of the WKUP1 pin has occurred since the last read of SUPC_SR. 1 (PRESENT): At least one wake-up due to the assertion of the WKUP1 pin has occurred since the last read of SUPC_SR. |
WKUPIS0 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS1 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS2 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS3 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS4 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS5 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS6 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS7 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS8 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS9 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS10 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS11 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS12 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS13 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS14 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |
WKUPIS15 | WKUPx Input Status (cleared on read) 0 (DIS): The corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake-up event. 1 (EN): The corresponding wake-up input was active at the time the debouncer triggered a wake-up event since the last read of SUPC_SR. |