BODDIS=ENABLE, BODRSTEN=NOT_ENABLE, OSCBYPASS=NO_EFFECT, ONREG=ONREG_UNUSED
Supply Controller Mode Register
BODRSTEN | Brownout Detector Reset Enable 0 (NOT_ENABLE): The core reset signal vddcore_nreset is not affected when a brownout detection occurs. 1 (ENABLE): The core reset signal, vddcore_nreset is asserted when a brownout detection occurs. |
BODDIS | Brownout Detector Disable 0 (ENABLE): The core brownout detector is enabled. 1 (DISABLE): The core brownout detector is disabled. |
ONREG | Voltage Regulator Enable 0 (ONREG_UNUSED): Internal voltage regulator is not used (external power supply is used). 1 (ONREG_USED): Internal voltage regulator is used. |
OSCBYPASS | Oscillator Bypass 0 (NO_EFFECT): No effect. Clock selection depends on the value of XTALSEL (SUPC_CR). 1 (BYPASS): The 32 kHz crystal oscillator is bypassed if XTALSEL (SUPC_CR) is set. OSCBYPASS must be set prior to setting XTALSEL. |
KEY | Password Key 165 (PASSWD): Writing any other value in this field aborts the write operation. |