Fujitsu /S6E2CC /CLK_GATING /CKEN1

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CKEN1

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (BTMCK0)BTMCK0 0 (BTMCK1)BTMCK1 0 (BTMCK2)BTMCK2 0 (BTMCK3)BTMCK3 0 (MFTCK0)MFTCK0 0 (MFTCK1)MFTCK1 0 (MFTCK2)MFTCK2 0 (MFTCK3)MFTCK3 0 (QDUCK0)QDUCK0 0 (QDUCK1)QDUCK1 0 (QDUCK2)QDUCK2 0 (QDUCK3)QDUCK3

Description

Peripheral Function Clock Control Register 1

Fields

BTMCK0

Settings operation clock supply and gating to base timer 0/1/2/3

BTMCK1

Settings operation clock supply and gating to base timer 4/5/6/7

BTMCK2

Settings operation clock supply and gating to base timer 8/9/10/11

BTMCK3

Settings operation clock supply and gating to base timer 12/13/14/15

MFTCK0

Settings for operation clock supply and gating of multi-function timer 0 and PPG 0/2/4/6

MFTCK1

Settings for operation clock supply and gating of multi-function timer 1 and PPG 8/10/12/14

MFTCK2

Settings for operation clock supply and gating of multi-function timer 2 and PPG 16/18/20/22

MFTCK3

Settings for operation clock supply and gating of multi-function timer 3 and PPG 24/26/28/30

QDUCK0

Reset control of quad counter unit 0

QDUCK1

Reset control of quad counter unit 1

QDUCK2

Reset control of quad counter unit 2

QDUCK3

Reset control of quad counter unit 3

Links

()