Infineon /XMC1300 /BCCU0 /EVFR

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as EVFR

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (value1)T0F 0 (value1)T1F 0 (value1)FF 0 (value1)EF 0 (value1)TPF 0 (value1)TPSF 0 (value1)TPINL

T1F=value1, TPSF=value1, TPF=value1, T0F=value1, TPINL=value1, EF=value1, FF=value1

Description

Event Flag

Fields

T0F

Trigger 0 Flag

0 (value1): No trigger event has been detected on BCCU trigger line 0 (BCCU_TRIGOUT0)

1 (value2): A trigger event has been detected on BCCU trigger line 0 (BCCU_TRIGOUT0)

T1F

Trigger 1 Flag

0 (value1): No trigger event has been detected on BCCU trigger line 1 (BCCU_TRIGOUT1)

1 (value2): A trigger event has been detected on BCCU trigger line 1 (BCCU_TRIGOUT1)

FF

FIFO Full Flag

0 (value1): No FIFO full event has been detected

1 (value2): A FIFO full event has been detected because one of the packer FIFOs is full and there has been a write attempt by the on-time or off-time counter

EF

FIFO Empty Flag

0 (value1): No FIFO full event has been detected

1 (value2): A FIFO full event has been detected because one of the packer FIFOs is empty and there has been a read attempt by the output generator

TPF

Trap Flag

0 (value1): No trap event has been detected

1 (value2): A trap event has been detected

TPSF

Trap State Flag

0 (value1): BCCU is not in a trap state

1 (value2): BCCU is in a trap state, the affected channel outputs are at their passive levels

TPINL

Trap Input Level

0 (value1): The current level of BCCU.TRAPL is low

1 (value2): The current level of BCCU.TRAPL is high

Links

()