Infineon /XMC1300 /CCU80_CC80 /DTC

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as DTC

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (value1)DTE1 0 (value1)DTE2 0 (value1)DCEN1 0 (value1)DCEN2 0 (value1)DCEN3 0 (value1)DCEN4 0 (value1)DTCC

DCEN2=value1, DTCC=value1, DCEN3=value1, DCEN1=value1, DTE2=value1, DTE1=value1, DCEN4=value1

Description

Dead Time Control

Fields

DTE1

Dead Time Enable for Channel 1

0 (value1): Dead Time for channel 1 is disabled

1 (value2): Dead Time for channel 1 is enabled

DTE2

Dead Time Enable for Channel 2

0 (value1): Dead Time for channel 2 is disabled

1 (value2): Dead Time for channel 2 is enabled

DCEN1

Dead Time Enable for CC8yST1

0 (value1): Dead Time for CC8yST1 path is disabled

1 (value2): Dead Time for CC8yST1 path is enabled

DCEN2

Dead Time Enable for inverted CC8yST1

0 (value1): Dead Time for inverted CC8yST1 path is disabled

1 (value2): Dead Time for inverted CC8yST1 path is enabled

DCEN3

Dead Time Enable for CC8yST2

0 (value1): Dead Time for CC8yST2 path is disabled

1 (value2): Dead Time for CC8yST2 path is enabled

DCEN4

Dead Time Enable for inverted CC8yST2

0 (value1): Dead Time for inverted CC8yST2 path is disabled

1 (value2): Dead Time for inverted CC8yST2 path is enabled

DTCC

Dead Time clock control

0 (value1): ftclk

1 (value2): ftclk/2

2 (value3): ftclk/4

3 (value4): ftclk/8