ECM=value1, SCE=value1, CMOD=value1, DIM=value1, ENDM=value1, CCS=value1, MCME2=value1, TRAPE0=value1, FPE=value1, STOS=value1, TRPSW=value1, EME=value1, TLS=value1, CAPC=value1, STRM=value1, TSSM=value1, TCM=value1, MCME1=value1, EMT=value1, EMS=value1, TRPSE=value1, DITHE=value1
Slice Timer Control
TCM | Timer Counting Mode 0 (value1): Edge aligned mode 1 (value2): Center aligned mode |
TSSM | Timer Single Shot Mode 0 (value1): Single shot mode is disabled 1 (value2): Single shot mode is enabled |
CLST | Shadow Transfer on Clear |
CMOD | Capture Compare Mode 0 (value1): Compare Mode 1 (value2): Capture Mode |
ECM | Extended Capture Mode 0 (value1): Normal Capture Mode. Clear of the Full Flag of each capture register is done by accessing the registers individually only. 1 (value2): Extended Capture Mode. Clear of the Full Flag of each capture register is done not only by accessing the individual registers but also by accessing the ECRD register. When reading the ECRD register, only the capture register register full flag pointed by the VPTR is cleared |
CAPC | Clear on Capture Control 0 (value1): Timer is never cleared on a capture event 1 (value2): Timer is cleared on a capture event into capture registers 2 and 3. (When SCE = 1#, Timer is always cleared in a capture event) 2 (value3): Timer is cleared on a capture event into capture registers 0 and 1. (When SCE = 1#, Timer is always cleared in a capture event) 3 (value4): Timer is always cleared in a capture event. |
TLS | Timer Load selector 0 (value1): Timer is loaded with the value of CR1 1 (value2): Timer is loaded with the value of CR2 |
ENDM | Extended Stop Function Control 0 (value1): Clears the timer run bit only (default stop) 1 (value2): Clears the timer only (flush) 2 (value3): Clears the timer and run bit (flush/stop) |
STRM | Extended Start Function Control 0 (value1): Sets run bit only (default start) 1 (value2): Clears the timer and sets run bit, if not set (flush/start) |
SCE | Equal Capture Event enable 0 (value1): Capture into CC8yC0VThis register contains the values associated with the Capture 0 field./CC8yC1VThis register contains the values associated with the Capture 1 field. registers control by CCycapt0 and capture into CC8yC3VThis register contains the values associated with the Capture 3 field./CC8yC2VThis register contains the values associated with the Capture 2 field. control by CCycapt1 1 (value2): Capture into CC8yC0VThis register contains the values associated with the Capture 0 field./CC8yC1VThis register contains the values associated with the Capture 1 field. and CC8yC3VThis register contains the values associated with the Capture 3 field./CC8yC2VThis register contains the values associated with the Capture 2 field. control by CCycapt1 |
CCS | Continuous Capture Enable 0 (value1): The capture into a specific capture register is done with the rules linked with the full flags, described at . 1 (value2): The capture into the capture registers is always done regardless of the full flag status (even if the register has not been read back). |
DITHE | Dither Enable 0 (value1): Dither is disabled 1 (value2): Dither is applied to the Period 2 (value3): Dither is applied to the Compare 3 (value4): Dither is applied to the Period and Compare |
DIM | Dither input selector 0 (value1): Slice is using it own dither unit 1 (value2): Slice is connected to the dither unit of slice 0. |
FPE | Floating Prescaler enable 0 (value1): Floating prescaler mode is disabled 1 (value2): Floating prescaler mode is enabled |
TRAPE0 | TRAP enable for CCU8x.OUTy0 0 (value1): TRAP functionality has no effect on the CCU8x.OUTy0 output 1 (value2): TRAP functionality affects the CCU8x.OUTy0 output |
TRAPE1 | TRAP enable for CCU8x.OUTy1 |
TRAPE2 | TRAP enable for CCU8x.OUTy2 |
TRAPE3 | TRAP enable for CCU8x.OUTy3 |
TRPSE | TRAP Synchronization Enable 0 (value1): Exiting from TRAP state isn’t synchronized with the PWM signal 1 (value2): Exiting from TRAP state is synchronized with the PWM signal |
TRPSW | TRAP State Clear Control 0 (value1): The slice exits the TRAP state automatically when the TRAP condition is not present (Trap state cleared by HW and SW) 1 (value2): The TRAP state can only be exited by a SW request. |
EMS | External Modulation Synchronization 0 (value1): External Modulation functionality is not synchronized with the PWM signal 1 (value2): External Modulation functionality is synchronized with the PWM signal |
EMT | External Modulation Type 0 (value1): External Modulation functionality is clearing the CC8ySTx bits. 1 (value2): External Modulation functionality is gating the outputs. |
MCME1 | Multi Channel Mode Enable for Channel 1 0 (value1): Multi Channel Mode in Channel 1 is disabled 1 (value2): Multi Channel Mode in Channel 1 is enabled |
MCME2 | Multi Channel Mode Enable for Channel 2 0 (value1): Multi Channel Mode in Channel 2 is disabled 1 (value2): Multi Channel Mode in Channel 2 is enabled |
EME | External Modulation Channel enable 0 (value1): External Modulation functionality doesn’t affect any channel 1 (value2): External Modulation only applied on channel 1 2 (value3): External Modulation only applied on channel 2 3 (value4): External Modulation applied on both channels |
STOS | Status bit output selector 0 (value1): CC8yST1 forward to CCU8x.STy 1 (value2): CC8yST2 forward to CCU8x.STy 2 (value3): CC8yST1 AND CC8yST2 forward to CCU8x.STy 3 (value4): CC8yST1 OR CC8yST2 forward to CCU8x.STy |