CMP_EN=value1, CMP_OUT=value1, ACMP2_SEL=value1, CMP_FLT_OFF=value1, CMP_INV_OUT=value1, CMP_HYST_ADJ=value1
Analog Comparator 2 Control Register
CMP_EN | Comparator enable 0 (value1): Comparator is disabled 1 (value2): Comparator is enabled |
CMP_FLT_OFF | Disables comparator filter 0 (value1): filter is active 1 (value2): filter is switched off (to prevent a filter delay) |
CMP_INV_OUT | Inverted Comparator output 0 (value1): no inversion of comparator signal 1 (value2): comparator signal is inverted |
CMP_HYST_ADJ | Comparator hysteresis adjust 0 (value1): Comparator hysteresis is switched off 1 (value2): Hysteresis_typ = 10mV 2 (value3): Hysteresis_typ = 15mV 3 (value4): Hysteresis_typ = 20mV |
ACMP2_SEL | Connect ACMP2.INP to ACMP1.INP 0 (value1): ACMP2.INP is not connected 1 (value2): ACMP2.INP is connected to ACMP1.INP |
CMP_OUT | Comparator output monitor bit 0 (value1): state “Vminus > Vplus” 1 (value2): state “Vminus < Vplus” |