ANRDY=value1, AREF=value1, STATE=value1, DIVS=value1, SP0=value1, ANOFF=value1, SCWC=value1, SP1=value1
SHS Configuration Register
DIVS | Divider Factor for the SHS Clock 0 (value1): fSH = fCONV / 1 1 (value2): fSH = fCONV / 2 15 (value3): fSH = fCONV / 16 |
AREF | Analog Reference Voltage Selection 0 (value1): External reference, upper supply range 2 (value3): Internal reference, upper supply range 3 (value4): Internal reference, lower supply range |
ANOFF | Analog Converter Power Down Force 0 (value1): Converter controlled by bitfields ANONS (digital control block) 1 (value2): Converter is permanently off |
ANRDY | Analog Converter Ready 0 (value1): Converter is in power-down mode 1 (value2): Converter is operable |
SCWC | Write Control for SHS Configuration 0 (value1): No write access to SHS configuration 1 (value2): Bitfields ANOFF, AREF, DIVS can be written |
SP0 | Sample Pending on S&H Unit x 0 (value1): No sample pending 1 (value2): S&H unit x has finished the sample phase |
SP1 | Sample Pending on S&H Unit x 0 (value1): No sample pending 1 (value2): S&H unit x has finished the sample phase |
TC | Test Control 11 (value1): Internal test functions enabled |
STATE | Current State of Sequencer 0 (value1): Idle 1 (value2): Offset calibration active 2 (value3): Gain calibration active 3 (value4): Startup calibration active 8 (value5): Stepper process active for S&H unit 0 9 (value6): Stepper process active for S&H unit 1 |