BDVTR=value1, BDSSM=value1, BPRIO=value1, BDV=value1, BDEN=value1
Bypass Control Register
BWLE | Bypass Word Length |
BDSSM | Bypass Data Single Shot Mode 0 (value1): The bypass data is still considered as valid after it has been loaded into TBUF. The loading of the data into TBUF does not clear BDV. 1 (value2): The bypass data is considered as invalid after it has been loaded into TBUF. The loading of the data into TBUF clears BDV. |
BDEN | Bypass Data Enable 0 (value1): The transfer of bypass data is disabled. 1 (value2): The transfer of bypass data to TBUF is possible. Bypass data will be transferred to TBUF according to its priority if BDV = 1. 2 (value3): Gated bypass data transfer is enabled. Bypass data will be transferred to TBUF according to its priority if BDV = 1 and while DX2S = 0. 3 (value4): Gated bypass data transfer is enabled. Bypass data will be transferred to TBUF according to its priority if BDV = 1 and while DX2S = 1. |
BDVTR | Bypass Data Valid Trigger 0 (value1): Bit BDV is not influenced by DX2T. 1 (value2): Bit BDV is set if DX2T is active. |
BPRIO | Bypass Priority 0 (value1): The transmit FIFO data has a higher priority than the bypass data. 1 (value2): The bypass data has a higher priority than the transmit FIFO data. |
BDV | Bypass Data Valid 0 (value1): The bypass data is not valid. 1 (value2): The bypass data is valid. |
BSELO | Bypass Select Outputs |
BHPC | Bypass Hardware Port Control |