Infineon /XMC1300 /VADC_G0 /QMR0

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as QMR0

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (value1)ENGT 0 (value1)ENTR 0 (value1)CLRV 0 (value1)TREV 0 (value1)FLUSH 0 (value1)CEV 0 (value1)RPTDIS

RPTDIS=value1, ENTR=value1, CEV=value1, CLRV=value1, ENGT=value1, TREV=value1, FLUSH=value1

Description

Queue 0 Mode Register

Fields

ENGT

Enable Gate

0 (value1): No conversion requests are issued

1 (value2): Conversion requests are issued if a valid conversion request is pending in the queue 0 register or in the backup register

2 (value3): Conversion requests are issued if a valid conversion request is pending in the queue 0 register or in the backup register and REQGTx = 1

3 (value4): Conversion requests are issued if a valid conversion request is pending in the queue 0 register or in the backup register and REQGTx = 0

ENTR

Enable External Trigger

0 (value1): External trigger disabled

1 (value2): The selected edge at the selected trigger input signal REQTR generates the trigger event

CLRV

Clear Valid Bit

0 (value1): No action

1 (value2): The next pending valid queue entry in the sequence and the event flag EV are cleared. If there is a valid entry in the queue backup register (QBUR.V = 1), this entry is cleared, otherwise the entry in queue register 0 is cleared.

TREV

Trigger Event

0 (value1): No action

1 (value2): Generate a trigger event by software

FLUSH

Flush Queue

0 (value1): No action

1 (value2): Clear all queue entries (including backup stage) and the event flag EV. The queue contains no more valid entry.

CEV

Clear Event Flag

0 (value1): No action

1 (value2): Clear bit EV

RPTDIS

Repeat Disable

0 (value1): A cancelled conversion is repeated

1 (value2): A cancelled conversion is discarded

Links

()