ST=value1
HRC current source for shadow
ST | Source selector for the shadow transfer 0 (value1): Shadow transfer signals (shadow transfer trigger and shadow transfer enable) are linked with the timer CC8y connected to the Source Selector 0. 1 (value2): Shadow transfer signals (shadow transfer trigger and shadow transfer enable) are linked with the timer CC8y connected to the Source Selector 1. |