RXIE=value1, DLCC=value1, IDC=value1, GDFS=value1, MMC=value1, RMM=value1, DATC=value1, FRREN=value1, TXIE=value1, OVIE=value1
Message Object Function Control Register
MMC | Message Mode Control 0 (value1): Standard Message Object 1 (value2): Receive FIFO Base Object 2 (value3): Transmit FIFO Base Object 3 (value4): Transmit FIFO Slave Object 4 (value5): Gateway Source Object |
GDFS | Gateway Data Frame Send 0 (value1): TXRQ is unchanged in the destination object. 1 (value2): TXRQ is set in the gateway destination object after the internal transfer from the gateway source to the gateway destination object. |
IDC | Identifier Copy 0 (value1): The identifier of the gateway source object is not copied. 1 (value2): The identifier of the gateway source object (after storing the received frame in the source) is copied to the gateway destination object. |
DLCC | Data Length Code Copy 0 (value1): Data length code is not copied. 1 (value2): Data length code of the gateway source object (after storing the received frame in the source) is copied to the gateway destination object. |
DATC | Data Copy 0 (value1): Data fields are not copied. 1 (value2): Data fields in registers MODATALn and MODATAHn of the gateway source object (after storing the received frame in the source) are copied to the gateway destination. |
RXIE | Receive Interrupt Enable 0 (value1): Message receive interrupt is disabled. 1 (value2): Message receive interrupt is enabled. |
TXIE | Transmit Interrupt Enable 0 (value1): Message transmit interrupt is disabled. 1 (value2): Message transmit interrupt is enabled. |
OVIE | Overflow Interrupt Enable 0 (value1): FIFO full interrupt is disabled. 1 (value2): FIFO full interrupt is enabled. |
FRREN | Foreign Remote Request Enable 0 (value1): TXRQ of message object n is set on reception of a matching Remote Frame. 1 (value2): TXRQ of the message object referenced by the pointer CUR is set on reception of a matching Remote Frame. |
RMM | Transmit Object Remote Monitoring 0 (value1): Remote monitoring is disabled: Identifier, IDE bit, and DLC of message object n remain unchanged upon the reception of a matching Remote Frame. 1 (value2): Remote monitoring is enabled: Identifier, IDE bit, and DLC of a matching Remote Frame are copied to transmit object n in order to monitor incoming Remote Frames. |
SDT | Single Data Transfer |
STT | Single Transmit Trial |
DLC | Data Length Code |