ASE=value1, OCS4=value1, OCS2=value1, OCS1=value1, OCS3=value1
Channel Control
ASE | Asymmetric PWM mode Enable 0 (value1): Asymmetric PWM is disabled 1 (value2): Asymmetric PWM is enabled |
OCS1 | Output selector for CCU8x.OUTy0 0 (value1): CC8yST1 signal path is connected to the CCU8x.OUTy0 1 (value2): Inverted CC8yST1 signal path is connected to the CCU8x.OUTy0 |
OCS2 | Output selector for CCU8x.OUTy1 0 (value1): Inverted CC8yST1 signal path is connected to the CCU8x.OUTy1 1 (value2): CC8yST1 signal path is connected to the CCU8x.OUTy1 |
OCS3 | Output selector for CCU8x.OUTy2 0 (value1): CC8yST2 signal path is connected to the CCU8x.OUTy2 1 (value2): Inverted CCST2 signal path is connected to the CCU8x.OUTy2 |
OCS4 | Output selector for CCU8x.OUTy3 0 (value1): Inverted CC8yST2 signal path is connected to the CCU8x.OUTy3 1 (value2): CC8yST2 signal path is connected to the CCU8x.OUTy3 |