Infineon /XMC4200 /SCU_PLL /PLLCON0

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as PLLCON0

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (value1)VCOBYP 0 (value1)VCOPWD 0 (value1)VCOTR 0 (value1)FINDIS 0 (value1)OSCDISCDIS 0 (value1)PLLPWD 0 (value1)OSCRES 0 (RESLD)RESLD 0 (value1)AOTREN 0 (value1)FOTR

FINDIS=value1, FOTR=value1, OSCRES=value1, AOTREN=value1, VCOPWD=value1, VCOTR=value1, VCOBYP=value1, PLLPWD=value1, OSCDISCDIS=value1

Description

PLL Configuration 0 Register

Fields

VCOBYP

VCO Bypass

0 (value1): Normal operation, VCO is not bypassed

1 (value2): Prescaler Mode, VCO is bypassed

VCOPWD

VCO Power Saving Mode

0 (value1): Normal behavior

1 (value2): The VCO is put into a Power Saving Mode and can no longer be used. Only the Bypass and Prescaler Mode are active if previously selected.

VCOTR

VCO Trim Control

0 (value1): VCO bandwidth is operation in the normal range. VCO output frequency is between 260 and 520 MHz for a input frequency between 8 and 16 MHz.

1 (value2): VCO bandwidth is operation in the test range. VCO output frequency is between 260 and 520 MHz for a input frequency between 8 and 16 MHz.

FINDIS

Disconnect Oscillator from VCO

0 (value1): connect oscillator to the VCO part

1 (value2): disconnect oscillator from the VCO part.

OSCDISCDIS

Oscillator Disconnect Disable

0 (value1): In case of a PLL loss-of-lock bit FINDIS is set

1 (value2): In case of a PLL loss-of-lock bit FINDIS is cleared

PLLPWD

PLL Power Saving Mode

0 (value1): Normal behavior

1 (value2): The complete PLL block is put into a Power Saving Mode and can no longer be used. Only the Bypass Mode is active if previously selected.

OSCRES

Oscillator Watchdog Reset

0 (value1): The Oscillator Watchdog of the PLL is not cleared and remains active

1 (value2): The Oscillator Watchdog of the PLL is cleared and restarted

RESLD

Restart VCO Lock Detection

AOTREN

Automatic Oscillator Calibration Enable

0 (value1): Disable

1 (value2): Enable

FOTR

Factory Oscillator Calibration

0 (value1): No effect

1 (value2): Force fixed-value trimming

Links

()