Infineon /XMC4200 /USIC0_CH0 /PSR_SSCMode

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as PSR_SSCMode

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (value1)MSLS 0 (value1)DX2S 0 (value1)MSLSEV 0 (value1)DX2TEV 0 (value1)PARERR 0 (value1)RSIF 0 (value1)DLIF 0 (value1)TSIF 0 (value1)TBIF 0 (value1)RIF 0 (value1)AIF 0 (value1)BRGIF

RIF=value1, TSIF=value1, AIF=value1, RSIF=value1, DLIF=value1, DX2TEV=value1, MSLSEV=value1, BRGIF=value1, TBIF=value1, PARERR=value1, DX2S=value1, MSLS=value1

Description

Protocol Status Register [SSC Mode]

Fields

MSLS

MSLS Status

0 (value1): The internal signal MSLS is inactive (0).

1 (value2): The internal signal MSLS is active (1).

DX2S

DX2S Status

0 (value1): DX2S is 0.

1 (value2): DX2S is 1.

MSLSEV

MSLS Event Detected

0 (value1): The MSLS signal has not changed its state.

1 (value2): The MSLS signal has changed its state.

DX2TEV

DX2T Event Detected

0 (value1): The DX2T signal has not been activated.

1 (value2): The DX2T signal has been activated.

PARERR

Parity Error Event Detected

0 (value1): A parity error event has not been activated.

1 (value2): A parity error event has been activated.

RSIF

Receiver Start Indication Flag

0 (value1): A receiver start event has not occurred.

1 (value2): A receiver start event has occurred.

DLIF

Data Lost Indication Flag

0 (value1): A data lost event has not occurred.

1 (value2): A data lost event has occurred.

TSIF

Transmit Shift Indication Flag

0 (value1): A transmit shift event has not occurred.

1 (value2): A transmit shift event has occurred.

TBIF

Transmit Buffer Indication Flag

0 (value1): A transmit buffer event has not occurred.

1 (value2): A transmit buffer event has occurred.

RIF

Receive Indication Flag

0 (value1): A receive event has not occurred.

1 (value2): A receive event has occurred.

AIF

Alternative Receive Indication Flag

0 (value1): An alternative receive event has not occurred.

1 (value2): An alternative receive event has occurred.

BRGIF

Baud Rate Generator Indication Flag

0 (value1): A baud rate generator event has not occurred.

1 (value2): A baud rate generator event has occurred.

Links

()