ARBRND=value1, BUSY=value1, CAL=value1, ANONS=value1, ARBM=value1, SAMPLE=value1
Arbitration Configuration Register
ANONC | Analog Converter Control |
ARBRND | Arbitration Round Length 0 (value1): 4 arbitration slots per round (tARB = 4 / fADCD) 1 (value2): 8 arbitration slots per round (tARB = 8 / fADCD) 2 (value3): 16 arbitration slots per round (tARB = 16 / fADCD) 3 (value4): 20 arbitration slots per round (tARB = 20 / fADCD) |
ARBM | Arbitration Mode 0 (value1): The arbiter runs permanently. This setting is required for a synchronization slave (see ) and for equidistant sampling using the signal ARBCNT (see ). 1 (value2): The arbiter only runs if at least one conversion request of an enabled request source is pending. This setting ensures a reproducible latency from an incoming request to the conversion start, if the converter is idle. Synchronized conversions are not supported. |
ANONS | Analog Converter Control Status 0 (value1): Analog converter off 3 (value4): Normal operation (permanently on) |
CAL | Start-Up Calibration Active Indication 0 (value1): Completed or not yet started 1 (value2): Start-up calibration phase is active |
BUSY | Converter Busy Flag 0 (value1): Not busy 1 (value2): Converter is busy with a conversion |
SAMPLE | Sample Phase Flag 0 (value1): Converting or idle 1 (value2): Input signal is currently sampled |