ENGT=value1, SCAN=value1, ENSI=value1, LDM=value1, RPTDIS=value1, CLRPND=value1, REQGT=value1, LDEV=value1, ENTR=value1
Autoscan Source Mode Register
ENGT | Enable Gate 0 (value1): No conversion requests are issued 1 (value2): Conversion requests are issued if at least one pending bit is set 2 (value3): Conversion requests are issued if at least one pending bit is set and REQGTx = 1. 3 (value4): Conversion requests are issued if at least one pending bit is set and REQGTx = 0. |
ENTR | Enable External Trigger 0 (value1): External trigger disabled 1 (value2): The selected edge at the selected trigger input signal REQTR generates the load event |
ENSI | Enable Source Interrupt 0 (value1): No request source interrupt 1 (value2): A request source interrupt is generated upon a request source event (last pending conversion is finished) |
SCAN | Autoscan Enable 0 (value1): No autoscan 1 (value2): Autoscan functionality enabled: a request source event automatically generates a load event |
LDM | Autoscan Source Load Event Mode 0 (value1): Overwrite mode: Copy all bits from the select registers to the pending registers upon a load event 1 (value2): Combine mode: Set all pending bits that are set in the select registers upon a load event (logic OR) |
REQGT | Request Gate Level 0 (value1): The gate input is low 1 (value2): The gate input is high |
CLRPND | Clear Pending Bits 0 (value1): No action 1 (value2): The bits in register GxASPNDx are cleared |
LDEV | Generate Load Event 0 (value1): No action 1 (value2): A load event is generated |
RPTDIS | Repeat Disable 0 (value1): A cancelled conversion is repeated 1 (value2): A cancelled conversion is discarded |