Infineon /XMC4200 /VADC_G0 /BFL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as BFL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (value1)BFL0 0 (value1)BFL1 0 (value1)BFL2 0 (value1)BFL3 0 (value1)BFA0 0 (value1)BFA1 0 (value1)BFA2 0 (value1)BFA3 0 (value1)BFI0 0 (value1)BFI1 0 (value1)BFI2 0 (value1)BFI3

BFI3=value1, BFI2=value1, BFL2=value1, BFL0=value1, BFI0=value1, BFA1=value1, BFA0=value1, BFL3=value1, BFA2=value1, BFA3=value1, BFI1=value1, BFL1=value1

Description

Boundary Flag Register

Fields

BFL0

Boundary Flag 0

0 (value1): Passive state: result has not yet crossed the activation boundary (see bitfield BFAy), or selected gate signal is inactive, or this boundary flag is disabled

1 (value2): Active state: result has crossed the activation boundary

BFL1

Boundary Flag 1

0 (value1): Passive state: result has not yet crossed the activation boundary (see bitfield BFAy), or selected gate signal is inactive, or this boundary flag is disabled

1 (value2): Active state: result has crossed the activation boundary

BFL2

Boundary Flag 2

0 (value1): Passive state: result has not yet crossed the activation boundary (see bitfield BFAy), or selected gate signal is inactive, or this boundary flag is disabled

1 (value2): Active state: result has crossed the activation boundary

BFL3

Boundary Flag 3

0 (value1): Passive state: result has not yet crossed the activation boundary (see bitfield BFAy), or selected gate signal is inactive, or this boundary flag is disabled

1 (value2): Active state: result has crossed the activation boundary

BFA0

Boundary Flag 0 Activation Select

0 (value1): Set boundary flag BFLy if result is above the defined band or compare value, clear if below

1 (value2): Set boundary flag BFLy if result is below the defined band or compare value, clear if above

BFA1

Boundary Flag 1 Activation Select

0 (value1): Set boundary flag BFLy if result is above the defined band or compare value, clear if below

1 (value2): Set boundary flag BFLy if result is below the defined band or compare value, clear if above

BFA2

Boundary Flag 2 Activation Select

0 (value1): Set boundary flag BFLy if result is above the defined band or compare value, clear if below

1 (value2): Set boundary flag BFLy if result is below the defined band or compare value, clear if above

BFA3

Boundary Flag 3 Activation Select

0 (value1): Set boundary flag BFLy if result is above the defined band or compare value, clear if below

1 (value2): Set boundary flag BFLy if result is below the defined band or compare value, clear if above

BFI0

Boundary Flag 0 Inversion Control

0 (value1): Use BFLy directly

1 (value2): Invert value and use BFLy

BFI1

Boundary Flag 1 Inversion Control

0 (value1): Use BFLy directly

1 (value2): Invert value and use BFLy

BFI2

Boundary Flag 2 Inversion Control

0 (value1): Use BFLy directly

1 (value2): Invert value and use BFLy

BFI3

Boundary Flag 3 Inversion Control

0 (value1): Use BFLy directly

1 (value2): Invert value and use BFLy

Links

()