ENGT=value1, TREV=value1, FLUSH=value1, CLRV=value1, CEV=value1, ENTR=value1, RPTDIS=value1
Queue 0 Mode Register
ENGT | Enable Gate 0 (value1): No conversion requests are issued 1 (value2): Conversion requests are issued if a valid conversion request is pending in the queue 0 register or in the backup register 2 (value3): Conversion requests are issued if a valid conversion request is pending in the queue 0 register or in the backup register and REQGTx = 1 3 (value4): Conversion requests are issued if a valid conversion request is pending in the queue 0 register or in the backup register and REQGTx = 0 |
ENTR | Enable External Trigger 0 (value1): External trigger disabled 1 (value2): The selected edge at the selected trigger input signal REQTR generates the trigger event |
CLRV | Clear Valid Bit 0 (value1): No action 1 (value2): The next pending valid queue entry in the sequence and the event flag EV are cleared. If there is a valid entry in the queue backup register (QBUR.V = 1), this entry is cleared, otherwise the entry in queue register 0 is cleared. |
TREV | Trigger Event 0 (value1): No action 1 (value2): Generate a trigger event by software |
FLUSH | Flush Queue 0 (value1): No action 1 (value2): Clear all queue entries (including backup stage) and the event flag EV. The queue contains no more valid entry. |
CEV | Clear Event Flag 0 (value1): No action 1 (value2): Clear bit EV |
RPTDIS | Repeat Disable 0 (value1): A cancelled conversion is repeated 1 (value2): A cancelled conversion is discarded |