VF12=value1, VF14=value1, VF15=value1, VF1=value1, VF7=value1, VF4=value1, VF13=value1, VF6=value1, VF10=value1, VF9=value1, VF2=value1, VF8=value1, VF5=value1, VF0=value1, VF3=value1, VF11=value1
Valid Flag Register
VF0 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF1 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF2 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF3 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF4 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF5 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF6 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF7 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF8 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF9 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF10 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF11 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF12 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF13 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF14 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |
VF15 | Valid Flag of Result Register x 0 (value1): Read access: No new valid data available Write access: No effect 1 (value2): Read access: Result register x contains valid data and has not yet been read, or bit FCR has been updated Write access: Clear this valid flag and bitfield DRC in register GxRESy (overrides a hardware set action) |