Infineon /XMC4700 /CAN_NODE0 /NECNT

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as NECNT

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0REC0TEC0EWRNLVL0 (value1)LETD 0 (value1)LEINC

LETD=value1, LEINC=value1

Description

Node Error Counter Register

Fields

REC

Receive Error Counter

TEC

Transmit Error Counter

EWRNLVL

Error Warning Level

LETD

Last Error Transfer Direction

0 (value1): The last error occurred while the CAN node x was receiver (REC has been incremented).

1 (value2): The last error occurred while the CAN node x was transmitter (TEC has been incremented).

LEINC

Last Error Increment

0 (value1): The last error led to an error counter increment of 1.

1 (value2): The last error led to an error counter increment of 8.

Links

()