HYST_UP_CH6=HYSTOFF, HYST_UP_CH7=HYSTOFF, CNT_UP_CH6=1, CNT_UP_CH5=1, CNT_UP_CH4=1, CNT_UP_CH7=1, HYST_UP_CH5=HYSTOFF, HYST_UP_CH4=HYSTOFF
Upper counter trigger level channel 4-7 register
CNT_UP_CH4 | Upper timer trigger threshold channel 4 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (16): 16 measurements 5 (32): 32 measurements 6 (63): 63 measurements 7 (63): 63 measurements |
HYST_UP_CH4 | Channel 4 upper hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |
CNT_UP_CH5 | Upper timer trigger threshold channel 5 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (16): 16 measurements 5 (32): 32 measurements 6 (63): 63 measurements 7 (63): 63 measurements |
HYST_UP_CH5 | Channel 5 upper hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |
CNT_UP_CH6 | Upper timer trigger threshold channel 6 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (16): 16 measurements 5 (32): 32 measurements 6 (63): 63 measurements 7 (63): 63 measurements |
HYST_UP_CH6 | Channel 6 upper hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |
CNT_UP_CH7 | Upper timer trigger threshold channel 7 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (16): 16 measurements 5 (32): 32 measurements 6 (63): 63 measurements 7 (63): 63 measurements |
HYST_UP_CH7 | Channel 7 upper hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |