Interpret as MOD

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (DISABLED)DCEN 0 (DIV1)T2PRE0 (DISABLED)PREN 0 (FALLING)EDGESEL 0 (DISABLED)T2RHEN 0 (FALLING)T2REGS

T2REGS=FALLING, T2RHEN=DISABLED, T2PRE=DIV1, DCEN=DISABLED, PREN=DISABLED, EDGESEL=FALLING

Description

Timer2 mode register

Fields

DCEN

Up/down counter enable

0 (DISABLED): Up/down counter function is disabled

1 (ENABLED): Up/down counter function is enabled and controlled by pin T2EX (up = 1, down = 0)

T2PRE

Timer2 prescaler bit

0 (DIV1): fT2=fSYS

1 (DIV2): fT2=fSYS/2

2 (DIV4): DfT2=fSYS/4

3 (DIV8): fT2=fSYS/8

4 (DIV16): fT2=fSYS/16

5 (DIV32): fT2=fSYS/32

6 (DIV64): fT2=fSYS/64

7 (DIV128): fT2=fSYS/128

PREN

Prescaler enable

0 (DISABLED): Prescaler is disabled and the 2 or 12 divider takes effect

1 (ENABLED): Prescaler is enabled (see T2PRE bit) and the 2 or 12 divider is bypassed

EDGESEL

Edge select in capture mode/reload mode

0 (FALLING): The falling edge at Pin T2EX is selected

1 (RISING): The rising edge at Pin T2EX is selected

T2RHEN

Timer2 external start enable

0 (DISABLED): Timer2 external start is disabled

1 (ENABLED): Timer2 external start is enabled

T2REGS

Edge select for Timer2 external start

0 (FALLING): The falling edge at pin T2EX is selected

1 (RISING): The rising edge at Pin T2EX is selected

Links

() ()