Interpret as CTRL1

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (stop)START 0 (software)TRIG_MODE 0 (atomic)CNV_MODE 0 (always)SAMP_CK_OFF 0TRIG_SEL 0 (dis)TS_SEL 0 (avg1)AVG0NUM_SLOTS

START=stop, SAMP_CK_OFF=always, TRIG_MODE=software, CNV_MODE=atomic, TS_SEL=dis, AVG=avg1

Description

Control Register 1.

Fields

START

Start conversion control.

0 (stop): Stop conversions.

1 (start): Start conversions.

TRIG_MODE

Trigger mode control.

0 (software): software trigger mode.

1 (hardware): hardware trigger mode.

CNV_MODE

Conversion mode control.

0 (atomic): Do one conversion sequence.

1 (continuous): Do continuous conversion sequences.

SAMP_CK_OFF

Sample clock off control.

0 (always): Sample clock always generated.

1 (cnv_only): Sample clock generated only when converting.

TRIG_SEL

Hardware trigger source select.

TS_SEL

Temp sensor select.

0 (dis): Temp sensor is not one of the slots in the sequence.

1 (en): Temp sensor is one of the slots in the sequence.

AVG

Number of samples to average for each output data code.

0 (avg1): 1 Sample per output code.

1 (avg2): 2 Samples per output code.

2 (avg4): 4 Samples per output code.

3 (avg8): 8 Samples per output code.

4 (avg16): 16 Samples per output code.

5 (avg32): 32 Samples per output code.

NUM_SLOTS

Number of slots enabled for the conversion sequence