LO=Dis, HI=Dis
Register for controlling SPI clock rate.
LO | Low duty cycle control. In timer mode, reload[7:0]. 0 (Dis): Duty cycle control of serial clock generation is disabled. |
HI | High duty cycle control. In timer mode, reload[15:8]. 0 (Dis): Duty cycle control of serial clock generation is disabled. |
CLKDIV | System Clock scale factor. Scales the AMBA clock by 2^SCALE before generating serial clock. |