TS_SEL=dis, SAMP_CK_OFF=always, CNV_MODE=atomic, TRIG_MODE=software, START=stop, AVG=avg1
Control Register 1.
START | Start conversion control. 0 (stop): Stop conversions. 1 (start): Start conversions. |
TRIG_MODE | Trigger mode control. 0 (software): software trigger mode. 1 (hardware): hardware trigger mode. |
CNV_MODE | Conversion mode control. 0 (atomic): Do one conversion sequence. 1 (continuous): Do continuous conversion sequences. |
SAMP_CK_OFF | Sample clock off control. 0 (always): Sample clock always generated. 1 (cnv_only): Sample clock generated only when converting. |
TRIG_SEL | Hardware trigger source select. |
TS_SEL | Temp sensor select. 0 (dis): Temp sensor is not one of the slots in the sequence. 1 (en): Temp sensor is one of the slots in the sequence. |
AVG | Number of samples to average for each output data code. 0 (avg1): 1 Sample per output code. 1 (avg2): 2 Samples per output code. 2 (avg4): 4 Samples per output code. 3 (avg8): 8 Samples per output code. 4 (avg16): 16 Samples per output code. 5 (avg32): 32 Samples per output code. |
NUM_SLOTS | Number of slots enabled for the conversion sequence |