WDSEL=B_0x0, PM=B_0x0, MSK2=B_0x0, MSK3=B_0x0, MSK1=B_0x0, MSK4=B_0x0
RTC alarm B register
SU | Second units in BCD format |
ST | Second tens in BCD format |
MSK1 | Alarm B seconds mask 0 (B_0x0): Alarm B set if the seconds match 1 (B_0x1): Seconds don’t care in alarm B comparison |
MNU | Minute units in BCD format |
MNT | Minute tens in BCD format |
MSK2 | Alarm B minutes mask 0 (B_0x0): Alarm B set if the minutes match 1 (B_0x1): Minutes don’t care in alarm B comparison |
HU | Hour units in BCD format |
HT | Hour tens in BCD format |
PM | AM/PM notation 0 (B_0x0): AM or 24-hour format 1 (B_0x1): PM |
MSK3 | Alarm B hours mask 0 (B_0x0): Alarm B set if the hours match 1 (B_0x1): Hours don’t care in alarm B comparison |
DU | Date units or day in BCD format |
DT | Date tens in BCD format |
WDSEL | Week day selection 0 (B_0x0): DU[3:0] represents the date units 1 (B_0x1): DU[3:0] represents the week day. DT[1:0] is don’t care. |
MSK4 | Alarm B date mask 0 (B_0x0): Alarm B set if the date and day match 1 (B_0x1): Date and day don’t care in alarm B comparison |