STMicroelectronics /STM32G0C1 /SPI1 /SPI_SR

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as SPI_SR

15 1211 87 43 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (B_0x0)RXNE 0 (B_0x0)TXE 0 (B_0x0)CHSIDE 0 (B_0x0)UDR 0 (B_0x0)CRCERR 0 (B_0x0)MODF 0 (B_0x0)OVR 0 (B_0x0)BSY 0 (B_0x0)FRE 0 (B_0x0)FRLVL 0 (B_0x0)FTLVL

MODF=B_0x0, FRE=B_0x0, CHSIDE=B_0x0, TXE=B_0x0, FTLVL=B_0x0, RXNE=B_0x0, UDR=B_0x0, OVR=B_0x0, CRCERR=B_0x0, FRLVL=B_0x0, BSY=B_0x0

Description

SPI status register

Fields

RXNE

Receive buffer not empty

0 (B_0x0): Rx buffer empty

1 (B_0x1): Rx buffer not empty

TXE

Transmit buffer empty

0 (B_0x0): Tx buffer not empty

1 (B_0x1): Tx buffer empty

CHSIDE

Channel side Note: This bit is not used in SPI mode. It has no significance in PCM mode.

0 (B_0x0): Channel Left has to be transmitted or has been received

1 (B_0x1): Channel Right has to be transmitted or has been received

UDR

Underrun flag This flag is set by hardware and reset by a software sequence. Refer to page 1057 for the software sequence. Note: This bit is not used in SPI mode.

0 (B_0x0): No underrun occurred

1 (B_0x1): Underrun occurred

CRCERR

CRC error flag Note: This flag is set by hardware and cleared by software writing 0. This bit is not used in I2S mode.

0 (B_0x0): CRC value received matches the SPI_RXCRCR value

1 (B_0x1): CRC value received does not match the SPI_RXCRCR value

MODF

Mode fault This flag is set by hardware and reset by a software sequence. Refer to (MODF) on page 1031 for the software sequence. Note: This bit is not used in I2S mode.

0 (B_0x0): No mode fault occurred

1 (B_0x1): Mode fault occurred

OVR

Overrun flag This flag is set by hardware and reset by a software sequence. Refer to page 1057 for the software sequence.

0 (B_0x0): No overrun occurred

1 (B_0x1): Overrun occurred

BSY

Busy flag This flag is set and cleared by hardware. Note: The BSY flag must be used with caution: refer to and .

0 (B_0x0): SPI (or I2S) not busy

1 (B_0x1): SPI (or I2S) is busy in communication or Tx buffer is not empty

FRE

Frame format error This flag is used for SPI in TI slave mode and I2S slave mode. Refer to error flags and . This flag is set by hardware and reset when SPI_SR is read by software.

0 (B_0x0): No frame format error

1 (B_0x1): A frame format error occurred

FRLVL

FIFO reception level These bits are set and cleared by hardware. Note: These bits are not used in I²S mode and in SPI receive-only mode while CRC calculation is enabled.

0 (B_0x0): FIFO empty

1 (B_0x1): 1/4 FIFO

2 (B_0x2): 1/2 FIFO

3 (B_0x3): FIFO full

FTLVL

FIFO transmission level These bits are set and cleared by hardware. Note: This bit is not used in I2S mode.

0 (B_0x0): FIFO empty

1 (B_0x1): 1/4 FIFO

2 (B_0x2): 1/2 FIFO

3 (B_0x3): FIFO full (considered as FULL when the FIFO threshold is greater than 1/2)