Access: No wait states, except if a write access occurs while a write access to this register is ongoing. In this case, wait states are inserted in the second write access until the previous one is completed. The latency of the second write access can be up to 2 x PCLK1 + 6 x I2CCLK.
TIMEOUTA | Bus Timeout A This field is used to configure: The SCL low timeout condition tTIMEOUT when TIDLE=0 tTIMEOUT= (TIMEOUTA+1) x 2048 x tI2CCLK The bus idle condition (both SCL and SDA high) when TIDLE=1 tIDLE= (TIMEOUTA+1) x 4 x tI2CCLK Note: These bits can be written only when TIMOUTEN=0. |
TIDLE | Idle clock timeout detection Note: This bit can be written only when TIMOUTEN=0. |
TIMOUTEN | Clock timeout enable |
TIMEOUTB | Bus timeout B This field is used to configure the cumulative clock extension timeout: In master mode, the master cumulative clock low extend time (tLOW:MEXT) is detected In slave mode, the slave cumulative clock low extend time (tLOW:SEXT) is detected tLOW:EXT= (TIMEOUTB+1) x 2048 x tI2CCLK Note: These bits can be written only when TEXTEN=0. |
TEXTEN | Extended clock timeout enable |