STMicroelectronics /STM32U073 /RCC /RCC_PLLCFGR

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as RCC_PLLCFGR

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (B_0x0)PLLSRC 0 (B_0x0)PLLM0 (B_0x0)PLLN0 (B_0x0)PLLPEN 0PLLP0 (B_0x0)PLLQEN 0PLLQ0 (B_0x0)PLLREN 0PLLR

PLLN=B_0x0, PLLREN=B_0x0, PLLQEN=B_0x0, PLLSRC=B_0x0, PLLPEN=B_0x0, PLLM=B_0x0

Description

PLL configuration register

Fields

PLLSRC

PLL input clock source This bit is controlled by software to select PLL clock source, as follows: The bitfield can be written only when the PLL is disabled. When the PLL is not used, selecting 00 allows saving power.

0 (B_0x0): No clock

1 (B_0x1): MSI

2 (B_0x2): HSI16

3 (B_0x3): HSE

PLLM

Division factor M of the PLL input clock divider This bit is controlled by software to divide the PLL input clock before the actual phase-locked loop, as follows: The bitfield can be written only when the PLL is disabled. Caution: The software must set these bits so that the PLL input frequency after the /M divider is between 2.66 and 161MHz.

0 (B_0x0): 1

1 (B_0x1): 2

2 (B_0x2): 3

3 (B_0x3): 4

4 (B_0x4): 5

5 (B_0x5): 6

6 (B_0x6): 7

7 (B_0x7): 8

PLLN

PLL frequency multiplication factor N This bit is controlled by software to set the division factor of the fVCO feedback divider (that determines the PLL multiplication ratio) as follows: … … The bitfield can be written only when the PLL is disabled. Caution: The software must set these bits so that the VCO output frequency is between 96 and 3441MHz.

0 (B_0x0): Invalid

4 (B_0x4): 4

5 (B_0x5): 5

126 (B_0x7E): 126

127 (B_0x7F): 127

PLLPEN

PLLPCLK clock output enable This bit is controlled by software to enable/disable the PLLPCLK clock output of the PLL: Disabling the PLLPCLK clock output, when not used, allows saving power.

0 (B_0x0): Disable

1 (B_0x1): Enable

PLLP

PLL VCO division factor P for PLLPCLK clock output This bitfield is controlled by software. It sets the PLL VCO division factor P as follows: … The bitfield can be written only when the PLL is disabled. Caution: The software must set this bitfield so as not to exceed 541MHz on this clock.

1 (B_0x1): 2

31 (B_0x1F): 32

PLLQEN

PLLQCLK clock output enable This bit is controlled by software to enable/disable the PLLQCLK clock output of the PLL: Disabling the PLLQCLK clock output, when not used, allows saving power.

0 (B_0x0): Disable

1 (B_0x1): Enable

PLLQ

PLL VCO division factor Q for PLLQCLK clock output This bitfield is controlled by software. It sets the PLL VCO division factor Q as follows: The bitfield can be written only when the PLL is disabled. Caution: The software must set this bitfield so as not to exceed 541MHz on this clock.

1 (B_0x1): 2

2 (B_0x2): 3

3 (B_0x3): 4

4 (B_0x4): 5

5 (B_0x5): 6

6 (B_0x6): 7

7 (B_0x7): 8

PLLREN

PLLRCLK clock output enable This bit is controlled by software to enable/disable the PLLRCLK clock output of the PLL: This bit cannot be written when PLLRCLK output of the PLL is selected for system clock. Disabling the PLLRCLK clock output, when not used, allows saving power.

0 (B_0x0): Disable

1 (B_0x1): Enable

PLLR

PLL VCO division factor R for PLLRCLK clock output This bitfield is controlled by software. It sets the PLL VCO division factor R as follows: The bitfield can be written only when the PLL is disabled. The PLLRCLK clock can be selected as system clock. Caution: The software must set this bitfield so as not to exceed 122MHz on this clock.

1 (B_0x1): 2

2 (B_0x2): 3

3 (B_0x3): 4

4 (B_0x4): 5

5 (B_0x5): 6

6 (B_0x6): 7

7 (B_0x7): 8