STMicroelectronics /STM32U575 /MDF1 /MDF_SCD2CR

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as MDF_SCD2CR

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (SCDEN)SCDEN 0BKSCD0SCDT0 (SCDACTIVE)SCDACTIVE

Description

This register is used for the adjustment stream delays.

Fields

SCDEN

Short circuit detector enable Set and cleared by software. - 0: The short circuit detector is disabled, - 1: The short circuit detector is enabled,

BKSCD

Break signal assignment for short circuit detector Set and cleared by software. BKSCD[i] = 0: Break signal (mdf_break[i]) is not assigned to this SCD event BKSCD[i] = 1: Break signal (mdf_break[i]) is assigned to this SCD event This field can be write-protected, please refer to Section 1.4.15: Register protection for details.

SCDT

Short-circuit detector threshold Set and cleared by software. These bits are written by software to define the threshold counter for the short-circuit detector. If this value is reached, then a short-circuit detector event occurs on a given input stream. - 0: 2 consecutive 1 s or 0 s will generate an event, - 1: 2 consecutive 1 s or 0 s will generate an event - 2: 3 consecutive 1 s or 0 s will generate an event, … - 255: 256 consecutive 1 s or 0 s will generate an event, This field can be write-protected, please refer to Section 1.4.15: Register protection for details.

SCDACTIVE

SCD Active flag Set and cleared by hardware. This flag must be used by the application in order to check if the SCD is effectively enabled (active) or not. The protected fields of this function can only be updated when the SCDACTIVE is set to a , please refer to Section 1.4.15: Register protection for details. The delay between a transition on SCDEN and a transition on SCDACTIVE is 2 periods of AHB clock and 2 periods of mdf_proc_ck. - 0: The SCD is not active, and can be configured if needed - 1: The SCD is active, and protected fields cannot be configured.

Links

()