This register is used for the adjustment of the Out-off Limit high threshold.
OLDTHH | OLD High Threshold Value Set and cleared by software. OLDTHH represents a 26-bit signed value. The real threshold compared to the signal provided by the filter is OLDTHH. This field can be write-protected, please refer to Section 1.4.15: Register protection for details |