SMPTRIG=B_0x0, BULB=B_0x0, JOVSE=B_0x0, OVSR=B_0x0, ROVSE=B_0x0, TROVS=B_0x0, SWTRIG=B_0x0, OVSS=B_0x0, ROVSM=B_0x0
ADC configuration register 2
ROVSE | Regular oversampling Enable 0 (B_0x0): Regular oversampling disabled 1 (B_0x1): Regular oversampling enabled |
JOVSE | Injected oversampling Enable 0 (B_0x0): Injected oversampling disabled 1 (B_0x1): Injected oversampling enabled |
OVSR | Oversampling ratio 0 (B_0x0): 2x 1 (B_0x1): 4x 2 (B_0x2): 8x 3 (B_0x3): 16x 4 (B_0x4): 32x 5 (B_0x5): 64x 6 (B_0x6): 128x 7 (B_0x7): 256x |
OVSS | Oversampling shift 0 (B_0x0): No shift 1 (B_0x1): Shift 1-bit 2 (B_0x2): Shift 2-bits 3 (B_0x3): Shift 3-bits 4 (B_0x4): Shift 4-bits 5 (B_0x5): Shift 5-bits 6 (B_0x6): Shift 6-bits 7 (B_0x7): Shift 7-bits 8 (B_0x8): Shift 8-bits |
TROVS | Triggered Regular oversampling 0 (B_0x0): All oversampled conversions for a channel are done consecutively following a trigger 1 (B_0x1): Each oversampled conversion for a channel needs a new trigger |
ROVSM | Regular oversampling mode 0 (B_0x0): Continued mode: When injected conversions are triggered, the oversampling is temporary stopped and continued after the injection sequence (oversampling buffer is maintained during injected sequence) 1 (B_0x1): Resumed mode: When injected conversions are triggered, the current oversampling is aborted and resumed from start after the injection sequence (oversampling buffer is zeroed by injected sequence start) |
SWTRIG | Software trigger bit for sampling time control trigger mode 0 (B_0x0): Software trigger starts the conversion for sampling time control trigger mode 1 (B_0x1): Software trigger starts the sampling for sampling time control trigger mode |
BULB | Bulb sampling mode 0 (B_0x0): Bulb sampling mode disabled 1 (B_0x1): Bulb sampling mode enabled. |
SMPTRIG | Sampling time control trigger mode 0 (B_0x0): Sampling time control trigger mode disabled 1 (B_0x1): Sampling time control trigger mode enabled |