START=B_0x0
FMAC parameter register
P | Input parameter P. The value of this parameter is dependent on the function This bitfield can not be modified when a function is ongoing (START = 1) |
Q | Input parameter Q. The value of this parameter is dependent on the function. This bitfield can not be modified when a function is ongoing (START = 1) |
R | Input parameter R. The value of this parameter is dependent on the function. This bitfield can not be modified when a function is ongoing (START = 1) |
FUNC | Function 2: Load X2 buffer 3: Load Y buffer 4 to 7: Reserved 8: Convolution (FIR filter) 9: IIR filter (direct form 1) This bitfield can not be modified when a function is ongoing (START = 1) 1 (B_0x1): Load X1 buffer |
START | Enable execution Setting this bit triggers the execution of the function selected in the FUNC bitfield. Resetting it by software stops any ongoing function. For initialization functions, this bit is reset by hardware. 0 (B_0x0): Stop execution 1 (B_0x1): Start execution |