ADCAL=B_0x0, DEEPPWD=B_0x0, ADEN=B_0x0, ADSTART=B_0x0, JADSTART=B_0x0, ADSTP=B_0x0, ADCALDIF=B_0x0, JADSTP=B_0x0, ADDIS=B_0x0
ADC control register
ADEN | ADC enable control 0 (B_0x0): ADC is disabled (OFF state) 1 (B_0x1): Write 1 to enable the ADC. |
ADDIS | ADC disable command 0 (B_0x0): no ADDIS command ongoing 1 (B_0x1): Write 1 to disable the ADC. Read 1 means that an ADDIS command is in progress. |
ADSTART | ADC start of regular conversion 0 (B_0x0): No ADC regular conversion is ongoing. 1 (B_0x1): Write 1 to start regular conversions. Read 1 means that the ADC is operating and eventually converting a regular channel. |
JADSTART | ADC start of injected conversion 0 (B_0x0): No ADC injected conversion is ongoing. 1 (B_0x1): Write 1 to start injected conversions. Read 1 means that the ADC is operating and eventually converting an injected channel. |
ADSTP | ADC stop of regular conversion command 0 (B_0x0): No ADC stop regular conversion command ongoing 1 (B_0x1): Write 1 to stop regular conversions ongoing. Read 1 means that an ADSTP command is in progress. |
JADSTP | ADC stop of injected conversion command 0 (B_0x0): No ADC stop injected conversion command ongoing 1 (B_0x1): Write 1 to stop injected conversions ongoing. Read 1 means that an ADSTP command is in progress. |
DEEPPWD | Deep-power-down enable 0 (B_0x0): ADC not in Deep-power down 1 (B_0x1): ADC in Deep-power-down (default reset state) |
ADCALDIF | Differential mode for calibration 0 (B_0x0): Single-ended input calibration mode. 1 (B_0x1): Differential input calibration mode. |
ADCAL | ADC calibration 0 (B_0x0): Normal mode 1 (B_0x1): Calibration mode |