stm32 /stm32n6 /STM32N647 /BSEC /BSEC_OTPVLDR1

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as BSEC_OTPVLDR1

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (B_0x0)VLDF32 0 (B_0x0)VLDF33 0 (B_0x0)VLDF34 0 (B_0x0)VLDF35 0 (B_0x0)VLDF36 0 (B_0x0)VLDF37 0 (B_0x0)VLDF38 0 (B_0x0)VLDF39 0 (B_0x0)VLDF40 0 (B_0x0)VLDF41 0 (B_0x0)VLDF42 0 (B_0x0)VLDF43 0 (B_0x0)VLDF44 0 (B_0x0)VLDF45 0 (B_0x0)VLDF46 0 (B_0x0)VLDF47 0 (B_0x0)VLDF48 0 (B_0x0)VLDF49 0 (B_0x0)VLDF50 0 (B_0x0)VLDF51 0 (B_0x0)VLDF52 0 (B_0x0)VLDF53 0 (B_0x0)VLDF54 0 (B_0x0)VLDF55 0 (B_0x0)VLDF56 0 (B_0x0)VLDF57 0 (B_0x0)VLDF58 0 (B_0x0)VLDF59 0 (B_0x0)VLDF60 0 (B_0x0)VLDF61 0 (B_0x0)VLDF62 0 (B_0x0)VLDF63

VLDF63=B_0x0, VLDF62=B_0x0, VLDF51=B_0x0, VLDF33=B_0x0, VLDF50=B_0x0, VLDF48=B_0x0, VLDF57=B_0x0, VLDF40=B_0x0, VLDF49=B_0x0, VLDF59=B_0x0, VLDF45=B_0x0, VLDF58=B_0x0, VLDF39=B_0x0, VLDF38=B_0x0, VLDF36=B_0x0, VLDF47=B_0x0, VLDF44=B_0x0, VLDF61=B_0x0, VLDF60=B_0x0, VLDF52=B_0x0, VLDF41=B_0x0, VLDF54=B_0x0, VLDF53=B_0x0, VLDF42=B_0x0, VLDF46=B_0x0, VLDF35=B_0x0, VLDF43=B_0x0, VLDF56=B_0x0, VLDF37=B_0x0, VLDF55=B_0x0, VLDF32=B_0x0, VLDF34=B_0x0

Description

BSEC OTP valid register 1

Fields

VLDF32

Valid flag for shadow register 32

0 (B_0x0): An error occurred while fuse word 32 was last reloaded. The value read from BSEC_FVR32 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 32 was done without error.

VLDF33

Valid flag for shadow register 33

0 (B_0x0): An error occurred while fuse word 33 was last reloaded. The value read from BSEC_FVR33 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 33 was done without error.

VLDF34

Valid flag for shadow register 34

0 (B_0x0): An error occurred while fuse word 34 was last reloaded. The value read from BSEC_FVR34 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 34 was done without error.

VLDF35

Valid flag for shadow register 35

0 (B_0x0): An error occurred while fuse word 35 was last reloaded. The value read from BSEC_FVR35 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 35 was done without error.

VLDF36

Valid flag for shadow register 36

0 (B_0x0): An error occurred while fuse word 36 was last reloaded. The value read from BSEC_FVR36 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 36 was done without error.

VLDF37

Valid flag for shadow register 37

0 (B_0x0): An error occurred while fuse word 37 was last reloaded. The value read from BSEC_FVR37 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 37 was done without error.

VLDF38

Valid flag for shadow register 38

0 (B_0x0): An error occurred while fuse word 38 was last reloaded. The value read from BSEC_FVR38 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 38 was done without error.

VLDF39

Valid flag for shadow register 39

0 (B_0x0): An error occurred while fuse word 39 was last reloaded. The value read from BSEC_FVR39 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 39 was done without error.

VLDF40

Valid flag for shadow register 40

0 (B_0x0): An error occurred while fuse word 40 was last reloaded. The value read from BSEC_FVR40 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 40 was done without error.

VLDF41

Valid flag for shadow register 41

0 (B_0x0): An error occurred while fuse word 41 was last reloaded. The value read from BSEC_FVR41 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 41 was done without error.

VLDF42

Valid flag for shadow register 42

0 (B_0x0): An error occurred while fuse word 42 was last reloaded. The value read from BSEC_FVR42 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 42 was done without error.

VLDF43

Valid flag for shadow register 43

0 (B_0x0): An error occurred while fuse word 43 was last reloaded. The value read from BSEC_FVR43 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 43 was done without error.

VLDF44

Valid flag for shadow register 44

0 (B_0x0): An error occurred while fuse word 44 was last reloaded. The value read from BSEC_FVR44 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 44 was done without error.

VLDF45

Valid flag for shadow register 45

0 (B_0x0): An error occurred while fuse word 45 was last reloaded. The value read from BSEC_FVR45 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 45 was done without error.

VLDF46

Valid flag for shadow register 46

0 (B_0x0): An error occurred while fuse word 46 was last reloaded. The value read from BSEC_FVR46 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 46 was done without error.

VLDF47

Valid flag for shadow register 47

0 (B_0x0): An error occurred while fuse word 47 was last reloaded. The value read from BSEC_FVR47 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 47 was done without error.

VLDF48

Valid flag for shadow register 48

0 (B_0x0): An error occurred while fuse word 48 was last reloaded. The value read from BSEC_FVR48 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 48 was done without error.

VLDF49

Valid flag for shadow register 49

0 (B_0x0): An error occurred while fuse word 49 was last reloaded. The value read from BSEC_FVR49 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 49 was done without error.

VLDF50

Valid flag for shadow register 50

0 (B_0x0): An error occurred while fuse word 50 was last reloaded. The value read from BSEC_FVR50 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 50 was done without error.

VLDF51

Valid flag for shadow register 51

0 (B_0x0): An error occurred while fuse word 51 was last reloaded. The value read from BSEC_FVR51 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 51 was done without error.

VLDF52

Valid flag for shadow register 52

0 (B_0x0): An error occurred while fuse word 52 was last reloaded. The value read from BSEC_FVR52 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 52 was done without error.

VLDF53

Valid flag for shadow register 53

0 (B_0x0): An error occurred while fuse word 53 was last reloaded. The value read from BSEC_FVR53 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 53 was done without error.

VLDF54

Valid flag for shadow register 54

0 (B_0x0): An error occurred while fuse word 54 was last reloaded. The value read from BSEC_FVR54 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 54 was done without error.

VLDF55

Valid flag for shadow register 55

0 (B_0x0): An error occurred while fuse word 55 was last reloaded. The value read from BSEC_FVR55 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 55 was done without error.

VLDF56

Valid flag for shadow register 56

0 (B_0x0): An error occurred while fuse word 56 was last reloaded. The value read from BSEC_FVR56 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 56 was done without error.

VLDF57

Valid flag for shadow register 57

0 (B_0x0): An error occurred while fuse word 57 was last reloaded. The value read from BSEC_FVR57 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 57 was done without error.

VLDF58

Valid flag for shadow register 58

0 (B_0x0): An error occurred while fuse word 58 was last reloaded. The value read from BSEC_FVR58 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 58 was done without error.

VLDF59

Valid flag for shadow register 59

0 (B_0x0): An error occurred while fuse word 59 was last reloaded. The value read from BSEC_FVR59 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 59 was done without error.

VLDF60

Valid flag for shadow register 60

0 (B_0x0): An error occurred while fuse word 60 was last reloaded. The value read from BSEC_FVR60 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 60 was done without error.

VLDF61

Valid flag for shadow register 61

0 (B_0x0): An error occurred while fuse word 61 was last reloaded. The value read from BSEC_FVR61 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 61 was done without error.

VLDF62

Valid flag for shadow register 62

0 (B_0x0): An error occurred while fuse word 62 was last reloaded. The value read from BSEC_FVR62 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 62 was done without error.

VLDF63

Valid flag for shadow register 63

0 (B_0x0): An error occurred while fuse word 63 was last reloaded. The value read from BSEC_FVR63 register cannot be relied on.

1 (B_0x1): Last reload of fuse word 63 was done without error.

Links

()