DTMODE=B_0x0, PIPEDIFF=B_0x0, FDTFEN=B_0x0, PIPEN=B_0x0
DCMIPP Pipe1 current flow selection configuration register
DTIDA | Current data type ID A |
DTIDB | Current data type ID B |
DTMODE | Flow selection mode 0 (B_0x0): Only flow DTID A from the selected virtual channel is forwarded in the pipe. 1 (B_0x1): Flows DTIDA and DTIDB from the selected virtual channel are forwarded in the pipe. This combination is valid only if the FDTFEN bit is set. |
PIPEDIFF | Current differentiates Pipe2 vs. Pipe1 0 (B_0x0): Pipe2 gets Pipe1 pixels after their processing in shared Gamma, StatRemoval, Demosaicing. Pipe2 shares the same VC DTID of Pipe1 when a CSI2 camera sensor is plugged. 1 (B_0x1): Pipe1 gets pixels from only VC/DTID configured in pipe1, processed by all including Gamma, StatRemoval, Demosaicing. Pipe2 gets pixels from only VC/DTID configured in Pipe2, processed from Crop only (Gamma common with Pipe1, no StatRem, no demosaicing) |
VC | Current flow selection mode |
FDTF | Current force data type format |
FDTFEN | Current force data type format enable 0 (B_0x0): Disable force data type format. The data type format used by the pipe is the one defined into DTIDx 1 (B_0x1): Enable force data type format. When the data type DTIDx is detected by the pipe, the real pixel format considering by the pipe is the one set into the FDTF[5:0] bit field instead of the physical one received by the CSI2 host. It allows to handle, for instance, 3D sensors camera with user data type in bottom-up approach, and to explicitly define the pixel format to be handled by the pipe. |
PIPEN | Current activation of PipeN 0 (B_0x0): Pipe disabled 1 (B_0x1): Pipe enabled, can start capturing with CPTMODE, CPTREQ, CPTACK. |