BOOTMODE=B_0x0, WAITRESP=B_0x0, BOOTEN=B_0x0
SDMMC command register
CMDINDEX | Command index |
CMDTRANS | The CPSM treats the command as a data transfer command, stops the interrupt period, and signals DataEnable to the DPSM |
CMDSTOP | The CPSM treats the command as a Stop Transmission command and signals abort to the DPSM |
WAITRESP | Wait for response bits 0 (B_0x0): No response, expect CMDSENT flag 1 (B_0x1): Short response, expect CMDREND or CCRCFAIL flag 2 (B_0x2): Short response, expect CMDREND flag (No CRC) 3 (B_0x3): Long response, expect CMDREND or CCRCFAIL flag |
WAITINT | CPSM waits for interrupt request |
WAITPEND | CPSM waits for end of data transfer (CmdPend internal signal) from DPSM |
CPSMEN | Command path state machine (CPSM) enable bit |
DTHOLD | Hold new data block transmission and reception in the DPSM |
BOOTMODE | Select the boot mode procedure to be used 0 (B_0x0): Normal boot mode procedure selected 1 (B_0x1): Alternative boot mode procedure selected. |
BOOTEN | Enable boot mode procedure 0 (B_0x0): Boot mode procedure disabled 1 (B_0x1): Boot mode procedure enabled |
CMDSUSPEND | The CPSM treats the command as a Suspend or Resume command and signals interrupt period start/end |