stm32 /stm32n6 /STM32N655 /FDCAN1 /FDCAN_TTOCN

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as FDCAN_TTOCN

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (SGT)SGT 0 (ECS)ECS 0 (B_0x0)SWP 0 (B_0x0)SWS0 (B_0x0)RTIE 0 (B_0x0)TMC0 (B_0x0)TTIE 0 (B_0x0)GCS 0 (B_0x0)FGP 0 (B_0x0)TMG 0 (B_0x0)NIG 0 (B_0x0)ESCN 0 (B_0x0)LCKC

SWP=B_0x0, NIG=B_0x0, ESCN=B_0x0, TTIE=B_0x0, TMC=B_0x0, TMG=B_0x0, SWS=B_0x0, GCS=B_0x0, LCKC=B_0x0, FGP=B_0x0, RTIE=B_0x0

Description

FDCAN TT operation control register

Fields

SGT

Set global time.

ECS

External clock synchronization.

SWP

Stop watch polarity.

0 (B_0x0): Rising edge trigger

1 (B_0x1): Falling edge trigger

SWS

Stop watch source.

0 (B_0x0): Stop watch disabled

1 (B_0x1): Actual value of cycle time is copied to FDCAN_TTCPT.SWV

2 (B_0x2): Actual value of local time is copied to FDCAN_TTCPT.SWV

3 (B_0x3): Actual value of global time is copied to FDCAN_TTCPT.SWV

RTIE

Register time mark interrupt pulse enable.

0 (B_0x0): Register time mark interrupt output disabled

1 (B_0x1): Register time mark interrupt output enabled

TMC

Register time mark compare.

0 (B_0x0): No Register time mark interrupt generated

1 (B_0x1): Register time mark interrupt if time mark = cycle time

2 (B_0x2): Register time mark interrupt if time mark = local time

3 (B_0x3): Register time mark interrupt if time mark = global time

TTIE

Trigger time mark interrupt pulse enable

0 (B_0x0): Trigger time mark interrupt output fdcan1_tmp for more than one instance and fdcan_tmp if only one instance disabled

1 (B_0x1): Trigger time mark interrupt output fdcan1_tmp for more than one instance and fdcan_tmp if only one instance enabled

GCS

Gap control select

0 (B_0x0): Gap control independent from event trigger

1 (B_0x1): Gap control by input event trigger pin

FGP

Finish gap.

0 (B_0x0): No reference message requested

1 (B_0x1): Application requested start of reference message

TMG

Time mark gap.

0 (B_0x0): Reset by each reference message

1 (B_0x1): Next reference message started when register time mark interrupt FDCAN_TTIR.RTMI is activated

NIG

Next is gap.

0 (B_0x0): No action, reset by reception of any reference message

1 (B_0x1): Transmit next reference message with Next_is_Gap = 1

ESCN

External synchronization control

0 (B_0x0): External synchronization disabled

1 (B_0x1): External synchronization enabled

LCKC

TT operation control register locked.

0 (B_0x0): Write access to FDCAN_TTOCN enabled

1 (B_0x1): Write access to FDCAN_TTOCN locked

Links

()