VBATL=B_0x0, TEMPL=B_0x0, MONEN=B_0x0, TEMPH=B_0x0, VBATH=B_0x0
PWR backup domain control register 1
MONEN | Vless thansub>BATless than/sub> and temperature monitoring enable 0 (B_0x0): Vless thansub>BATless than/sub> and temperature monitoring disabled 1 (B_0x1): Vless thansub>BATless than/sub> and temperature monitoring enabled |
VBATL | Vless thansub>BATless than/sub> level monitoring versus low threshold 0 (B_0x0): Vless thansub>BATless than/sub> level above low threshold level 1 (B_0x1): Vless thansub>BATless than/sub> level equal or below low threshold level |
VBATH | Vless thansub>BATless than/sub> level monitoring versus high threshold 0 (B_0x0): Vless thansub>BATless than/sub> level below high threshold level. 1 (B_0x1): Vless thansub>BATless than/sub> level equal or above high threshold level |
TEMPL | Temperature level monitoring versus low threshold 0 (B_0x0): Temperature above low threshold level 1 (B_0x1): Temperature equal or below low threshold level |
TEMPH | Temperature level monitoring versus high threshold 0 (B_0x0): Temperature below high threshold level 1 (B_0x1): Temperature equal or above high threshold level |