FMT=B_0x0, TSCO=B_0x0, HOFFAS=B_0x0
I3C get capability register
HOFFAS | Controller hand-off activity state 0 (B_0x0): activity state 0 is the initial activity state of this I3C before and when becoming controller 1 (B_0x1): activity state 1 is the initial activity state of this I3C when becoming controller 2 (B_0x2): activity state 2 is the initial activity state of this I3C when becoming controller 3 (B_0x3): activity state 3 is the initial activity state of this I3C when becoming controller |
FMT | GETMXDS CCC format 0 (B_0x0): format 1 (2 bytes with MaxWr with no defining byte, MaxRd) 1 (B_0x1): format 2: (5 bytes w.ith MaxWr with no defining byte, MaxRd, MaxRdTurn) 2 (B_0x2): format 2 (5 bytes with MaxWr with no defining byte, MaxRd, and middle byte of MaxRdTurn) 3 (B_0x3): format 2 (5 bytes with MaxWr with no defining byte, MaxRd, MSB of MaxRdTurn) |
RDTURN | programmed byte of the 3-byte MaxRdTurn (maximum read turnaround byte) |
TSCO | clock-to-data turnaround time (tless thansub>SCOless than/sub>) 0 (B_0x0): tless thansub>SCOless than/sub> less than or equal to 12 ns 1 (B_0x1): tless thansub>SCOless than/sub> > 12 ns (refer to the datasheet for more details) |