THINB=B_0x0, ACICN=B_0x0, OLDACTIVE=B_0x0, ACICD=B_0x0, OLDEN=B_0x0
MDF out-of limit detector control register 4
OLDEN | OLDx enable 0 (B_0x0): OLDx disabled (default value) 1 (B_0x1): OLDx enabled, including the ACIC filter working in continuous mode |
THINB | Threshold In band 0 (B_0x0): The OLDx generates an event if the signal is lower than OLDTHL or higher than OLDTHH (default value). 1 (B_0x1): The OLDx generates an event if the signal is lower than OLDTHH and higher than OLDTHL |
BKOLD | Break signal assignment for out-of limit detector |
ACICN | OLDx CIC order selection 0 (B_0x0): FastSinc filter type 1 (B_0x1): Sincless thansup>1less than/sup> filter type 2 (B_0x2): Sincless thansup>2less than/sup> filter type 3 (B_0x3): Sincless thansup>3less than/sup> filter type |
ACICD | OLDx CIC decimation ratio selection 0 (B_0x0): Decimation ratio is 1. 1 (B_0x1): Decimation ratio is 2. |
OLDACTIVE | OLDx active flag 0 (B_0x0): OLDx not active and can be configured if needed 1 (B_0x1): OLDx active and protected fields cannot be configured |