CALP=B_0x0, LPCAL=B_0x0
RTC calibration register
CALM | Calibration minus |
LPCAL | RTC low-power mode 0 (B_0x0): Calibration window is 2less thansup>20less than/sup> RTCCLK, which is a high-consumption mode. This mode must be set only when less than 32s calibration window is required. 1 (B_0x1): Calibration window is 2less thansup>20less than/sup> ck_apre, which is the required configuration for ultra-low consumption mode. |
CALW16 | Use a 16-second calibration cycle period |
CALW8 | Use an 8-second calibration cycle period |
CALP | Increase frequency of RTC by 488.5 ppm 0 (B_0x0): No RTCCLK pulses are added. 1 (B_0x1): One RTCCLK pulse is effectively inserted every 2less thansup>11less than/sup> pulses (frequency increased by 488.5 ppm). |