DMAMUX request line multiplexer interrupt channel status register
| SOF0 | Synchronization overrun event flag The flag is set when a synchronization event occurs on a DMA request line multiplexer channel x, while the DMA request counter value is lower than NBREQ. The flag is cleared by writing 1 to the corresponding CSOFx bit in DMAMUX_CFR register. |
| SOF1 | Synchronization overrun event flag The flag is set when a synchronization event occurs on a DMA request line multiplexer channel x, while the DMA request counter value is lower than NBREQ. The flag is cleared by writing 1 to the corresponding CSOFx bit in DMAMUX_CFR register. |
| SOF2 | Synchronization overrun event flag The flag is set when a synchronization event occurs on a DMA request line multiplexer channel x, while the DMA request counter value is lower than NBREQ. The flag is cleared by writing 1 to the corresponding CSOFx bit in DMAMUX_CFR register. |
| SOF3 | Synchronization overrun event flag The flag is set when a synchronization event occurs on a DMA request line multiplexer channel x, while the DMA request counter value is lower than NBREQ. The flag is cleared by writing 1 to the corresponding CSOFx bit in DMAMUX_CFR register. |
| SOF4 | Synchronization overrun event flag The flag is set when a synchronization event occurs on a DMA request line multiplexer channel x, while the DMA request counter value is lower than NBREQ. The flag is cleared by writing 1 to the corresponding CSOFx bit in DMAMUX_CFR register. |
| SOF5 | Synchronization overrun event flag The flag is set when a synchronization event occurs on a DMA request line multiplexer channel x, while the DMA request counter value is lower than NBREQ. The flag is cleared by writing 1 to the corresponding CSOFx bit in DMAMUX_CFR register. |
| SOF6 | Synchronization overrun event flag The flag is set when a synchronization event occurs on a DMA request line multiplexer channel x, while the DMA request counter value is lower than NBREQ. The flag is cleared by writing 1 to the corresponding CSOFx bit in DMAMUX_CFR register. |
| SOF7 | Synchronization overrun event flag The flag is set when a synchronization event occurs on a DMA request line multiplexer channel x, while the DMA request counter value is lower than NBREQ. The flag is cleared by writing 1 to the corresponding CSOFx bit in DMAMUX_CFR register. |
| SOF8 | Synchronization overrun event flag The flag is set when a synchronization event occurs on a DMA request line multiplexer channel x, while the DMA request counter value is lower than NBREQ. The flag is cleared by writing 1 to the corresponding CSOFx bit in DMAMUX_CFR register. |
| SOF9 | Synchronization overrun event flag The flag is set when a synchronization event occurs on a DMA request line multiplexer channel x, while the DMA request counter value is lower than NBREQ. The flag is cleared by writing 1 to the corresponding CSOFx bit in DMAMUX_CFR register. |
| SOF10 | Synchronization overrun event flag The flag is set when a synchronization event occurs on a DMA request line multiplexer channel x, while the DMA request counter value is lower than NBREQ. The flag is cleared by writing 1 to the corresponding CSOFx bit in DMAMUX_CFR register. |
| SOF11 | Synchronization overrun event flag The flag is set when a synchronization event occurs on a DMA request line multiplexer channel x, while the DMA request counter value is lower than NBREQ. The flag is cleared by writing 1 to the corresponding CSOFx bit in DMAMUX_CFR register. |